Items Method Condition Unit Typical Value
Tg IPC-TM-650 2.4.25 DSC ℃ 155
Td IPC-TM-650 2.4.24.6 5% wt. loss ℃ 355
CTE (Z-axis) IPC-TM-650 2.4.24 Before Tg ppm/℃ 40
After Tg ppm/℃ 230
50-260℃ % 2.8
T260 IPC-TM-650 2.4.24.1 TMA min >60
T288 IPC-TM-650 2.4.24.1 TMA min >60
Thermal Stress IPC-TM-650 2.4.13.1 288℃, solder dip s >100
Volume Resistivity IPC-TM-650 2.5.17.1 C-96/35/90 MΩ.cm 1.15E+08
Surface Resistivity IPC-TM-650 2.5.17.1 C-96/35/90 MΩ 9.61E+06
Arc Resistance IPC-TM-650 2.5.1 D-48/50+D-4/23 s 178
Dielectric Breakdown IPC-TM-650 2.5.6 D-48/50+D-4/23 kV >45
Permittivity (1GHz) IPC-TM-650 2.5.5.9 C-24/23/50 -- 4.5
Loss Tangent (1GHz) IPC-TM-650 2.5.5.9 C-24/23/50 -- 0.011
Peel Strength (1 oz) IPC-TM-650 2.4.8 288℃,10s N/mm[lb/in] 1.5[8.57]
Flexural Strength LW IPC-TM-650 2.4.4 A MPa 630
CW IPC-TM-650 2.4.4 A MPa 480
Water Absorption IPC-TM-650 2.6.2.1 D-24/23 % 0.1
Flammability UL94 C-48/23/50 Rating V-0
CTI IEC 60112 A Grade PLC 1*

Remarks:

1. Specification sheet: IPC-4101/128, is for your reference only.

2. All the typical value is based on the 1.6mm specimen, while the Tg is for specimen≥0.50mm.

3. All the typical values listed above are for your reference only and not intended for specification. Please contact Shengyi Technology Co., Ltd. for detailed information. All rights from this data sheet are reserved by Shengyi Technology Co., Ltd.

Explanation: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning

The first digit following the letter indicates the duration of preconditioning in hours, the second digit the preconditioning temperature in ℃ and the third digit the relative humidity.